GE SERVOSTAR 310
GE SERVOSTAR 310 is a member of the MVAJ23 series high-burden tripping relays manufactured for power-system protection and circuit-breaker control applications. The MVAJ23 series is a double-element tripping relay designed to provide reliable operation of circuit-breaker trip circuits and associated protection schemes.
The relay is primarily used as an interface between a protection system and the circuit-breaker trip mechanism. When a protection device issues a trip command, the relay operates its output contacts to initiate circuit-breaker tripping and, depending on the configuration, maintain the trip/lockout condition until the appropriate reset operation is performed.
2. Technical Parameters
| Item | Description |
|---|---|
| Manufacturer | GE / GEC ALSTHOM |
| Product Series | SERVOSTAR 310 |
| Model | SERVOSTAR 310 |
| Relay Type | High-Burden Tripping / Lockout Relay |
| Series Configuration | MVAJ23 Double-Element Tripping Relay |
| Primary Function | Circuit-breaker tripping and protection output |
| Application | Protection, control and trip circuits |
| Operating Principle | Electromagnetic relay operation |
| Contact Configuration | Determined by the specific model configuration |
| Coil / Auxiliary Voltage | Must be verified from the product nameplate and configuration |
| Mounting | Protection and control panel installation |
| Construction | Electromechanical relay |
| Typical Environment | Substations, power plants and industrial power systems |
| Product Status | Legacy/discontinued product family |
3. Product Features
3.1 High-Burden Design
The SERVOSTAR 310 is designed as a high-burden tripping relay, making it suitable for applications where the relay must reliably drive or interface with demanding trip circuits.
3.2 Reliable Circuit-Breaker Tripping
The relay provides a dependable interface between the protection system and the circuit-breaker trip circuit. Its electromechanical construction is well suited to critical protection applications.
3.3 Lockout Function
Depending on the specific configuration, the relay can maintain its operated condition following a protection trip, helping prevent unintended re-energization until the appropriate reset procedure has been completed.
3.4 Robust Electromechanical Construction
The traditional electromagnetic construction provides electrical isolation between control and output circuits and offers good resistance to the electrical disturbances commonly encountered in substation environments.
3.5 Suitable for Legacy Protection Systems
The SERVOSTAR 310 series is particularly relevant to existing installations using GEC ALSTHOM and legacy GE protection and control equipment, where maintaining the original protection architecture is important.
4. Structural Composition
The GE SERVOSTAR 310 typically consists of the following functional sections:
- Electromagnetic Operating Mechanism
The coil and magnetic circuit generate the force required to operate the relay. - Mechanical Operating Mechanism
Transfers the electromagnetic movement to the contact assembly. - Output Contact Assembly
Provides the electrical interface to the circuit-breaker trip circuit and associated control circuits. - Holding / Lockout Mechanism
Maintains the operated condition when the application requires a lockout function. - Reset Mechanism
Allows the relay to return to its normal state after the protection operation, according to the particular configuration. - Housing and Terminal Assembly
Provides mechanical protection, mounting and electrical connections.
5. Application Fields
Power Substations
Used in protection panels for high-voltage and extra-high-voltage substations, particularly for circuit-breaker trip and lockout circuits.
Power Generation Plants
Can be used in generator protection, switchyard protection and circuit-breaker control systems.
Transmission and Distribution Systems
Suitable for legacy protection systems where reliable transmission of a protection trip command is required.
Industrial Power Systems
Applicable to critical electrical systems in industries such as oil and gas, petrochemical, metallurgy, mining and large manufacturing facilities.
Maintenance of Legacy Equipment
The SERVOSTAR 310 can be particularly valuable as a maintenance or spare component for existing GEC ALSTHOM/GE protection systems.
6. Selection and Replacement Considerations
When replacing SERVOSTAR 310 , the following items should be carefully verified:
- Complete model number: SERVOSTAR 310
- Coil or auxiliary voltage
- Number and type of contacts
- Terminal numbering
- Wiring configuration
- Mechanical dimensions
- Mounting arrangement
- Reset method
- Original protection-system logic
- Protection-panel wiring diagrams
- Product nameplate and terminal information
Replacement should not be based solely on the MVAJ23 series designation, because different suffix configurations may have different electrical and mechanical characteristics.
7. Conclusion
The GE SERVOSTAR 310 is a high-burden electromechanical tripping/lockout relay designed for critical power-system protection and circuit-breaker control applications. It provides a reliable interface between protection equipment and circuit-breaker trip circuits and is well suited to traditional substation and power-generation protection systems.













There are no reviews yet.